• CALL US: 570-823-6181 | FREE DOMESTIC SHIPPING ON ORDERS OVER $1,000 | Your trusted industrial supplier!

  • CALL US: 570-823-6181 | FREE DOMESTIC SHIPPING ON ORDERS OVER $1,000 | Your trusted industrial supplier!

Home > Control Power Solutions > Dry Type Transformers > General Purpose Transformers

General Purpose Transformers

SolaHD General Purpose Transformers

SolaHD General Purpose Transformers provide reliable voltage transformation and electrical isolation for industrial, commercial and institutional power-distribution applications. These energy-efficient, ventilated dry-type transformers are available in 600 Volt Class single-phase and three-phase configurations from 15 kVA through 500 kVA.

General purpose transformers are used when the available source voltage must be changed to match the voltage required by connected equipment or an electrical distribution system. Common applications include motors, lighting, heating equipment, machinery, facility power systems and other inductive or resistive loads.

SolaHD General Purpose Transformers feature a UL Class 220°C insulation system with a 150°C temperature rise under full load. Their terminal-board connections, spacious wiring compartments and accessible panel-enclosure design help simplify installation and field wiring. Applicable models meet DOE 2016 and NRCan 2019 energy-efficiency requirements.

SolaHD General Purpose Transformer Selection Data

The official SolaHD datasheet includes available catalog numbers, kVA ratings, primary and secondary voltage combinations, dimensions, shipping weights, electrical connections, wiring diagrams and compatible Type 3R weather shields.

Download the SolaHD General Purpose Transformers Datasheet (PDF)

Browse the available SolaHD General Purpose Transformers below. Wallco Inc. can assist with selecting the correct transformer based on the available primary voltage, required secondary voltage, phase, connected load and installation environment.

Filters

Filters

Sort By:
Products per page

About SolaHD General Purpose Transformers

SolaHD General Purpose Transformers are ventilated dry-type distribution transformers designed for applications where voltage must be changed to match the requirements of an electrical circuit or connected equipment. They are classified as isolation transformers, providing separate primary and secondary windings for voltage transformation and electrical isolation.

These transformers may be installed close to the connected load, helping reduce the need for long feeder runs. They are commonly used throughout industrial plants, commercial buildings, offices, schools, hospitals, apartment buildings, shopping centers and other facilities requiring dependable electrical distribution.

Available Transformer Ratings

The SolaHD General Purpose Transformer family includes single-phase and three-phase models covering a broad range of standard kVA ratings. Available ratings vary by voltage configuration and may include:

  • 15 kVA
  • 25 kVA
  • 30 kVA
  • 37.5 kVA
  • 45 kVA
  • 50 kVA
  • 75 kVA
  • 100 kVA
  • 112.5 kVA
  • 150 kVA
  • 167 kVA
  • 225 kVA
  • 300 kVA
  • 500 kVA

Not every kVA rating is available with every primary and secondary voltage combination. Confirm the required phase, source voltage, load voltage and connected load before selecting a catalog number.

Common Voltage Configurations

Standard catalog configurations include a variety of commonly used industrial and commercial voltages, including:

  • 240 x 480 volt primary to 120/240 volt secondary
  • 120/208/240/277 volt primary to 120/240 volt secondary
  • 480 volt delta primary to 208Y/120 volt secondary
  • 480 volt delta primary to 240 volt delta secondary with a reduced-capacity 120 volt center tap
  • 480 volt delta primary to 480Y/277 volt secondary
  • 208 volt delta primary to 208Y/120 volt secondary
  • 208 volt delta primary to 480Y/277 volt secondary
  • 240 volt delta primary to 208Y/120 volt secondary
  • 240 volt delta primary to 480Y/277 volt secondary
  • 480 volt delta primary to 380Y/220 volt secondary
  • 600 volt delta primary to 208Y/120 volt secondary
  • 600 volt delta primary to 480Y/277 volt secondary

Availability and kVA ranges differ by voltage group. Review the SolaHD selection tables or contact Wallco before ordering.

Key Features

  • Energy-efficient ventilated dry-type construction
  • 600 Volt Class isolation-transformer designs
  • Single-phase and three-phase models
  • Available from 15 kVA through 500 kVA
  • Applicable models compliant with DOE 2016 and NRCan 2019 efficiency requirements
  • UL Class 220°C insulation system
  • 150°C temperature rise under full load
  • Quiet operation below applicable NEMA ST-20 sound-level requirements
  • Terminal-board connections
  • Spacious wiring compartments
  • Wiring diagram located inside the front cover
  • High-efficiency operation
  • Ten-year limited warranty
  • Made in the USA

Indoor and Outdoor Installations

Standard ventilated models are intended for appropriate indoor installations. Applicable transformers can be used in outdoor NEMA Type 3R applications when equipped with the correct SolaHD weather-shield kit.

The weather shields are ordered separately and must match the transformer catalog number and enclosure size. Do not assume that a standard ventilated transformer is suitable for outdoor installation without the required weather shield.

Common Applications

  • Industrial power distribution
  • Commercial building electrical systems
  • Manufacturing plants
  • Motors and machinery
  • Lighting systems
  • Heating equipment
  • Office buildings
  • Schools and universities
  • Hospitals and healthcare facilities
  • Apartment and multifamily buildings
  • Shopping centers
  • Institutional facilities
  • OEM equipment
  • Facility renovations and voltage conversions

How to Select a General Purpose Transformer

Correct transformer selection begins with the electrical requirements of the source and connected load. Confirm the following information before choosing a model:

  • Available primary or source voltage
  • Required secondary or load voltage
  • Single-phase or three-phase power
  • Connected load in amperes or kVA
  • Operating frequency
  • Indoor or outdoor installation
  • Required enclosure or weather protection
  • Need for an electrostatic shield
  • Aluminum or copper winding requirement
  • Applicable electrical-code requirements

Single-Phase Transformer Sizing

For a single-phase load, calculate the required transformer capacity using:

kVA = Volts × Amps ÷ 1,000

Three-Phase Transformer Sizing

For a three-phase load, calculate the required transformer capacity using:

kVA = Volts × Amps × 1.732 ÷ 1,000

Select a transformer with a nameplate kVA rating equal to or greater than the calculated connected load. Motor loads, future expansion, continuous loading and other application conditions may require additional sizing considerations.

Primary Voltage Taps

Many three-phase SolaHD General Purpose Transformers include primary voltage taps that allow the installer to compensate for variations in the incoming source voltage. The available tap arrangement depends on the transformer series and voltage configuration.

Voltage taps are intended for installation setup and are not automatic voltage regulators. Connections must be made according to the wiring diagram supplied with the transformer.

Accessories and Optional Designs

Depending on the model and application, SolaHD offers accessories and optional transformer designs that may include:

  • Electrostatic shielding for improved power quality
  • Wall-mounting brackets for qualifying transformer sizes and weights
  • UL Listed NEMA Type 3R weather shields
  • Stainless-steel enclosures
  • Open core-and-coil designs
  • Copper-wound designs
  • Configured voltage and kVA combinations

Standard SolaHD General Purpose Transformers commonly use aluminum coil windings. Copper-wound models are available for selected voltage configurations and ratings. Optional or configured designs may have different certifications, lead times and specifications.

Electrostatic Shielding

An electrostatic shield may be included on selected models or available as an optional design. Shielding can help reduce the transfer of line-to-ground electrical noise between the primary and secondary circuits.

Do not assume that every catalog number includes an electrostatic shield. Verify the individual model and selection table before ordering.

Enhanced Enclosure Features

Selected SolaHD models use enhanced enclosure designs intended to improve handling, access and installation. Depending on the catalog number, features may include:

  • Lower center of gravity
  • Visible mounting feet for forklift placement
  • Replaceable side, front, rear and top panels
  • Enhanced cage-nut fasteners
  • Accessible wiring compartments
  • Packaging tested to applicable ISTA standards

Certifications and Compliance

Applicable models are UL Listed under file E25872 and are designed to meet relevant dry-type transformer requirements. Selected models are also energy-efficiency verified. DOE 2016 and NRCan 2019 compliance varies by model and application, so certifications should be confirmed for the individual catalog number.

Outdoor suitability, enclosure classification, energy-efficiency compliance and optional-design certifications should always be verified before purchase or installation.

Frequently Asked Questions

What is a general purpose transformer?

A general purpose transformer is a dry-type isolation transformer used to change one standard supply voltage into another voltage required by an electrical circuit or connected load.

Are SolaHD General Purpose Transformers single phase or three phase?

The product family includes both single-phase and three-phase models. The transformer phase must match the electrical source and application requirements.

What sizes are available?

The overall family covers ratings from 15 kVA through 500 kVA. Available ratings vary according to phase and voltage configuration.

Can these transformers be installed outdoors?

Applicable ventilated models may be used in outdoor NEMA Type 3R installations when fitted with the correct optional SolaHD weather shields. Weather shields must be ordered separately.

Are copper windings available?

Standard general purpose models commonly use aluminum windings. Copper-wound versions are available for selected ratings and voltage combinations.

Can a transformer convert single-phase power to three-phase power?

No. A standard general purpose transformer changes voltage but does not convert a single-phase source into three-phase power or a three-phase source into single-phase power for an equivalent three-phase load.

How do I determine the correct kVA rating?

Use the source voltage, load current and phase to calculate the connected kVA, then select a transformer rated for at least that load. Additional capacity may be appropriate for motors, continuous loads or future expansion.

Why Buy SolaHD General Purpose Transformers from Wallco Inc.?

  • Factory Authorized SolaHD Distributor
  • Assistance selecting the proper voltage, phase and kVA rating
  • Support identifying compatible outdoor weather shields
  • Access to standard and configured transformer designs
  • Competitive industrial transformer pricing
  • Fast order processing
  • Industrial electrical product experience
  • Serving industrial customers since 1937

Need Help Selecting a Transformer?

Contact Wallco Inc. with the available primary voltage, required secondary voltage, phase, connected amperage or kVA, operating frequency and installation environment. We can help identify the appropriate SolaHD General Purpose Transformer and any required accessories.

Empty Cart